Wednesday, February 7, 2007

General Equipment

GR 200 Analytical Balance (210 *0.1mg)

See the complete technical balance specifications GR series







GX 600 with Standard Breeze break (610g *1mg)

Review all the specification and even download the instruction manual




MX-50 Moisture Analyser

A&D MX/MF Specifications

Download the MX/MF-50 Instruction Manual (2.2 MB)

Read More..

Tuesday, February 6, 2007

Spectrophotometer Genesys 20



Spectrophotometer
Model GENESYS 20

SPECIFICATIONS
Wavelength Range 325 to 1100 nm
Wavelength Accuracy ±2.0 nm
Wavelength Repeatability ±0.5 nm
Spectral Bandwidth 8 nm
Optical System Single-beam
Photometric Range -0.1 to 2.5A; 0 to 125%T; 0 to 1999C
Photometric Accuracy 0.003A (from 0 to 0.3A); 1% of reading (from 0.3A to 2.5A)
Photometric readout Abs, %T, Conc, Factor
Lamp Source Tungsten Lamp
Detector Solid-state detector
Monochromator Grating-based (1200 lines/mm)
Noise (peak-to-peak) <0.001A @ 0A; <0.002A @ 2A
Drift <0.003/hour
Stray Light (at 340 & 400 nm) <0.1%T
Display LCD; 20-character, 2-line
Supplied Interface RS232c; Centronics parallel
Supplied Cell Holder Single-cell for 10-mm pathlength square and test tube cuvettes
Test Storage One set of parameters in non-volatile memory
Data Storage External via RS232c
Languages English, Spanish, French, Czech, Portuguese, German
Power Requirements 100-240V, 50/60Hz
Dimensions 30cmW x 33cmD x 19cmH (11.8"W x 13"D x 7.5"H)
Weight 10 lbs (4.5 Kg)
Warranty 3 years

INCLUDES
Dust cover
Operator's manual
5 disposable cuvettes

Download Brochure

Read More..

ROTIXA 50S/RS

NEW
Floor-standing Centrifuges ROTIXA 50 S / 50 RS

Best High Sample Throughput

Among experts ROTIXA has become a household word for high sample throughput. This is why ROTIXA models are the centrifuges of choice in development and quality control laboratories of the life sciene industry and in medical routine laboratories.
With generating a maximum RCF of 5,503 ROTIXA centrifuges are suited for separating a wide range of sample materials such as samples of food, cell suspensions, sediments of chemical reactions, soil and, of course, blood and blood components.
In addition to all commonly used blood collection systems the ROTIXA 50 S and 50 RS centrifuges accommodate Falcon tubes, microtitre plates and centrifuge bottles up to a volume of 1,000 ml.
With the growing use of clinical chemistry analysers in mind, the ROTIXA 50 S and 50 RS centrifuges are also designed to spin racks of well-known manufacturers like Olympus, Hitachi, LKB, and Behring.
It goes without saying that they also accept the time-tested round-bottom tubes up to a max. volume of 250 ml.

Further details can be gathered from the brochure converted into a pdf file for downloading.